Permanent Magnetic Plate Lifter

  • Efficient lifting and handling operations
  • Secure lifting of magnetic materials
  • Lightweight and ingeniously structured design
  • Ideal for lifting iron docks, cylindrical objects, and other magnetic components

Please select Size

SKU: MGL Categories: Tag:
Permanent Magnetic Plate Lifte...

PERMANENT MAGNETIC PLATE LIFTER

Introducing the SSTC Permanent Magnetic Plate Lifter, Model MGL, a versatile and reliable tool designed for efficient lifting and handling operations in various industrial environments.  The permanent magnetic plate lifter utilizes powerful permanent magnets to securely connect components during lifting tasks, offering ease of operation, safety, and enhanced working efficiency.

Features:

  1. Utilizes permanent magnets for secure and reliable lifting of magnetic materials such as iron docks, cylindrical objects, and other magnetic components.
  2. Easy to operate, with a simple and ingeniously structured design that ensures safe handling and efficient lifting operations.
  3. Lightweight construction enhances maneuverability and reduces operator fatigue during extended use.
  4. Widely used as hoisting devices in factories, docks, warehouses, and transportation industries, offering flexibility and versatility in various applications.

 MEETS AND EXCEEDS STANDARDS:

EN 60404-5:2008, EN 13155:2003+A2:2009

Construction and Specifications:

 

MODEL MGL Permanent Magnetic Lifter has a strong magnetic path produced by NdFeB magnetic materials. On and off the magnetic path is controlled by turning the manual nozzle. There are shackles on the top of Magnetic Lifting Hoist for lifting, a V slot on the holding cylindrical component.

[wpdatatable id=76]

The main technical parameters are given as follows:

[wpdatatable id=77]


Applications:

  1. Ideal for lifting and handling magnetic materials in manufacturing plants, steel mills, and metalworking facilities.
  2. Suitable for connecting and transporting iron docks, cylindrical objects, and other magnetic components in construction and assembly processes.
  3. Enhances working conditions and increases working efficiency by providing a reliable and efficient method for lifting and handling magnetic materials.

How to Use:

  1. Position the permanent magnetic plate lifter over the magnetic material to be lifted, ensuring proper alignment.
  2. Engage the lifting mechanism to activate the permanent magnets, securely connecting the lifter to the material.
  3. Verify that the connection is secure and stable before lifting the material to the desired location.
  4. Use appropriate lifting equipment, such as cranes or hoists, to raise and transport the material to its destination.
  5. Once the material is in position, disengage the lifting mechanism to release the magnetic connection and safely lower the material.
  6. Store the permanent magnetic plate lifter in a secure location when not in use, taking care to protect the magnets from damage.

Experience the convenience, efficiency, and safety of the SSTC Permanent Magnetic Plate Lifter, an indispensable tool for lifting and handling magnetic materials in industrial settings. With its reliable performance and user-friendly design, this lifter is sure to improve your working conditions and increase your working efficiency.

Operating Instructions:

  1. During operation, you should clear away the components such as rust and burr. The center line of the lifter had better overlap with the centralizing of the component. Then place the Magnetic Lifting Hoist on the security key on the handle is automatically locked, and then start to hoist.
  2. During lifting and handling components, overloading is forbidden. Nobody is allowed to pass through under the component held by the Magnetic Lifter. Components temperature and ambient temperature shall be between +80℃ to -40℃. No strong vibration and impact.
  3. When lifting and handling cylindrical components, keeping the cylindrical surface contacting the “V” slot of the lifter on two lines the actual lifting capacity will generally be 30% of the rated lifting capacity.
  4. When the lifting and handling operation is finished, press down the bottom to disengage the security key from the security pin, and then turn the handle “ON” to “OFF” until released. The lifter is now in the neutral condition, it can be taken away from the component.

MAINTENANCE AND SAFETY INSTRUCTIONS FOR PERMANENT MAGNETIC PLATE LIFTER:

  1. While carrying and using a permanent magnetic lifter, beware of the bumping and roughness of the surface in order not to influence the property and life-span. After use, the lifter had better be protected by oil.
  2. Please read the operating instructions carefully and properties carefully before using this lifter to avoid an accident.
  3. Check the quality of the handle button frequently. Make sure that the security key can be moved flexibly and the security pin can be locked firmly.
  4. When the Magnetic Lifting Hoist is not in contact with the ferromagnetic material of the component, don’t turn the nozzle.
  5. Maintenance must be strictly according to the instructions by the professional authorized technical personnel.
  6. Prohibit modifying the products to avoid affecting their safety.
  7. Must take a test for the capability every week and check the safety of all of the components in order to ensure its use capability.
  8. If the main body and turning part are damaged and it can not work, it should be discarded as useless.
Precautions & FAQs

Reviews

There are no reviews yet.

Be the first to review “Permanent Magnetic Plate Lifter”

Your email address will not be published. Required fields are marked

Recommended

Request for Quotation

complete the form below to start discussing your lifting product needs.

Ask an expert

LET’S STAY IN TOUCH!

Subscribe & Get 15% Off On Your First Purchase

connect with us